General Specifications
  • Designed, built and tested to meet American Society of Mechanical Engineers (ASME) specifications
  • Vacuum/Perlite Insulation
  • Inner vessel material SA-612 normalized carbon steel
  • Outer vessel material ASTM A-36 structural grade carbon steel
  • Maximum Allowable Working Pressure (MAWP) 350 psig (2.413 Mpa)
  • Minimum Designed Metal Temperature (MDMT) -29.2°F (-34°C), or colder
  • Design pressure at least 10% above normal operating pressure
  • Designed for hurricane wind loads, and a wind speed of 110 mph (177 km/hr)
  • All stainless steel piping and ball valves. Stainless steel lifting lugs are standard on all horizontal units
  • Optional manway (cleaning and inspection) and vaporizers
  • Capped pressure building lines are standard
  • Optional capped refrigeration lines with internal coils
Note: All CO2 storage units are manufactured using normalized SA-612 carbon steel plate.

Horizontal Vacuum Insulated Weights/Dimensions
Model Nominal Capacity Height* Length* Width* Approx. Empty Weight
FTH 6.2 12,400 lbs 7'  1"  15' 2" 6' 11,900 lbs. 
5624.5 kg 2.16m 4.62m 1.83m 5397.8kg
FTH 14.3 28,600 lbs 8'  7" 19'  7" 7'  6" 22,600 lbs.
12973 kg 2.62m 5.97m 2.29m 10251kg
FTH 30.1 60,200 lbs 8'  7" 55'  7" 7'  6" 41,100 lbs.
27306 kg 2.62m 16.94m 2.29m 18643kg
FTH 50.3 100,600 lbs.  10' 40' 9'  6" 71,000 lbs.
45631 kg 3.05m 12.19m 2.90m 32205kg